Resistance Temperature Detectors (RTDs)
TLSR5
Description
This RTD sensor is designed for industrial applications.
The thermometer consists of a 6 mm diameter stem with either a transmitter mounting plate or a ceramic terminal block.
The terminal head can be selected from a wide choice of standard items. It also provides an extension neck, a hex nipple or a NUN neck with different lengths.
It can be installed into a thermowell by means of a fixed thread on the extension neck.



Design

Technical Specifications
Designation | Measuring range limits | ||
Measuring range | Pt100 per IEC 60751 | -200 to +600°C (-328 to +1112°F) | |
The above range may vary depending on limitations of electrical connection chosen and the jacket material of the insert. |
Type | Class | Max error |
|
Accuracy (IEC 60751) |
Wire-wound | B: -196 to +600°C | ±(0.30 + 0.0050.t) |
A: -100 to +450°C | ±(0.15 + 0.0020.t) | ||
AA: -50 to +250°C | ±(0.10 + 0.0017.t) | ||
Thin-film | B: -50 to +500°C | ±(0.30 + 0.0050.t) | |
A: -30 to +300°C | ±(0.15 + 0.0020.t) | ||
AA: 0 to +150°C | ±(0.10 + 0.0017.t) | ||
Operating conditions | Maximum ambient temperature | Without mounted head transmitter | Depends on the terminal head and the cable glands used |
With mounted head transmitter | -40 to 85°C (-40 to +185°F) |
Diameter (mm) |
Standard stocked grades |
||
Standard insert diameters |
6.0 | ASTM 316L | |
Standard process connections |
Fixed threads | ¼” NPT, ½” NPT, | |
G½” (BSPP) | |||
Material: SS316 |
Head, electrical connection and display
Head (terminal enclosure) | This product is available in the complete range of heads. Complete information on the various options is available in the Thermocouple and RTD Heads section. |
|
Transmitters (optional) | We can manufacture the thermocouples fitted with transmitters to increase accuracy and reliability compared to direct wired solutions. We offer a wide range of transmitters that are PC Programmable including: • HART® Programmable Transmitters • Profibus® PA Head Transmitters • Foundation Fieldbus™ Head Transmitters |
|
Displays (optional) | We can manufacture the thermocouples fitted with pluggable displays to indicate actual measured values, identification and fault events. This requires the use of a suitable terminal head with a display window. |