Resistance Temperature Detectors (RTDs)

TLSR5

Description

 

This RTD sensor is designed for industrial applications.

The thermometer consists of a 6 mm diameter stem with either a transmitter mounting plate or a ceramic terminal block.

The terminal head can be selected from a wide choice of standard items. It also provides an extension neck, a hex nipple or a NUN neck with different lengths.

It can be installed into a thermowell by means of a fixed thread on the extension neck.

 

 

 

TLSC1

Design

TLSR5 design

Technical Specifications

  Designation   Measuring range limits
Measuring range Pt100 per IEC 60751   -200 to +600°C (-328 to +1112°F)
  The above range may vary depending on limitations of electrical connection chosen and the jacket material of the insert.

 

  Type Class Max error
Accuracy
(IEC 60751)



Wire-wound B: -196 to +600°C ±(0.30 + 0.0050.t)
A: -100 to +450°C ±(0.15 + 0.0020.t)
AA: -50 to +250°C ±(0.10 + 0.0017.t)
Thin-film B: -50 to +500°C ±(0.30 + 0.0050.t)
A: -30 to +300°C ±(0.15 + 0.0020.t)
AA: 0 to +150°C ±(0.10 + 0.0017.t)
Operating conditions Maximum ambient temperature Without mounted head transmitter Depends on the terminal head and the cable glands used
With mounted head transmitter -40 to 85°C (-40 to +185°F)

 

  Diameter (mm)
  Standard stocked grades
Standard insert diameters


6.0   ASTM 316L
Standard process connections




Fixed threads   ¼” NPT, ½” NPT,
  G½” (BSPP)
  Material: SS316

Head, electrical connection and display

Head (terminal enclosure)   This product is available in the complete range of heads.
Complete information on the various options is available
in the Thermocouple and RTD Heads section.
Transmitters (optional)   We can manufacture the thermocouples fitted with transmitters
to increase accuracy and reliability compared to direct wired solutions.
We offer a wide range of transmitters that are PC Programmable including:
• HART® Programmable Transmitters
• Profibus® PA Head Transmitters
• Foundation Fieldbus™ Head Transmitters
Displays (optional)   We can manufacture the thermocouples fitted with pluggable displays
to indicate actual measured values, identification and fault events.
This requires the use of a suitable terminal head with a display window.